Programming information for PLAIN TK705/805 model (NOT "D" model)
For jumper settings to make sense, view this document in NOTE PAD with Fixed
system font or WORD PAD with Courier New Font


KENWOOD
T-89-49-LM
SERVICE BULLETIN  LAND MOBILE RADIO
DATE
TK-705/805 TECHNICAL INTRODUCTION AND SUPPLEMENT    09/08/89


The TK-705 and TK-805 utilize a self contained programmer (or KPT-40). Unless 
Kenwood has programmed the unit for you at the factory, these units are 
shipped in the "program mode". In the program mode, the radio will not 
transmit or receive (no receive audio). Before the radio will transmit or
receive it must be programmed according to the following pages. It also must
have the "user" mode selected. Inside the radio just to the left behind the
display is a jumper labeled CN7, this is a 3 pin plug with a shorting plug
placed across two of the pins. With the front of the radio toward you, when
the shorting plug is placed across the center and left most pin, the radio is
in programming, memory clear and clone mode.  When the shorting plug is
placed on the center and right most pin, the radio is in user mode.


CONDENSED PROGRAMMING INFORMATION


In the program mode the channel selector is used to select frequencies and QT
(CTCSS) tones. Holding the squelch switch while rotating the channel selector 
changes the frequency in I MHz steps. PTT enters the displayed information 
into memory and steps to the next setting. With the power switch off, holding 
the squelch switch while turning power on will provide temporary TX/RX for 
testing purposes (without selecting user mode). Turning the power switch on 
while pressing the monitor (speaker symbol) switch CLEARS ALL MEMORY.


PROGRAMMING ERRATA


In the user mode, the display will skip unprogrammed channels.


During programming a channel location which displays only dashes (---.----) 
has not been programmed The hundreds digit, in a 12.5kc (TK805) or 6.25kc 
(optional in TK705) channel step will not be displayed. A hundreds digit will 
be indicated by a dot,'.' after the last digit of the frequency display.


If an optional PLL channel step is to be used, the radio must be modified
accordingly prior to programming.


CH 1 cannot be deleted. Once channel are programmed, they cannot be deleted 
unless memory is cleared (see above) and all but the undesired channel(s) are
reprogrammed. (Previously programmed memories can be reprogrammed)
Tone programming "OFF" indicates that tone is disabled either encode or 
decode). When "OFF" is displayed, rotating the channel selector will allow 
selection of the desired tone. (Tone will be skipped if no board installed.)


When all desired tone and frequency entries are completed continue pressing 
PTT to step across the unprogrammed channels until end is displayed. If any 
undesired channels were displayed prior to "END", the memory must be cleared 
and reprogrammed.


The TK705/805 Tuning manual references function I and function II. Function I 
refers to the program mode and Function II refers to the USER mode.


The TK705/805 in its basic form (when ordered unprogrammed) is shipped with
both the Time Out timer and Busy Channel lockout disabled. Plug-in jumpers 
are used to select the desired function for these features. The Time out timer
selects length of transmission before transmitter will automatically unkey.


Time out timer selection jumpers
      JUMPER          OFF      30 sec       60 sec     90 sec
      CN6            | |-|     |-| |        | |-|      |-| |
      CN5            | |-|     | |-|        |-| |      |-| |


 |-| | refers to jumpers on left most two pins and | |-| refers to jumpers on
right most two pins of three pin set facing front of radio 


Busy channel lockout, selects whether transmitter can be keyed on a busy channel.
    JUMPER      Enabled     Disabled
    CN8          |-| |       | |-|


Selection of programming/user mode.
    JUMPER      Program      User  
     CN7          |-| |      | |-|


On TK705/TK805, PLL frequency step size is selected by soldering chip jumpers 
on the TX/RX unit (B/2) board foil side.


R207 installed and R208 removed equals 10kc steps on 805 (5kc on 705), R207 
and R208 removed equals 12.5kc steps on 805 (6.25kc on 705).


SAMPLE PROGRAMMING - SET CN7 to PROGRAMMING POSITION   (|-| |)


CLEAR ALL MEMORY, hold monitor switch while turning on power, memory is 
erased, frequency setting mode is entered automatically.


OR turn unit on, channel 1 receive frequency setting will be displayed.
(450.000 initial setting)


FREQUENCY SETTING MODE, rotate channel selector mode to set receive 
frequency, change in 1 MHz steps by holding down squelch button while 
rotating channel selector.  Press PTT to set and go to tone selection.  If no 
tone signaling board is installed this will not be displayed.


TONE, Select "OFF" or rotate channel selector knob to select tone frequency. 
Press PTT to set


Transmit frequency, (TX arrow symbol in display), set transmit frequency as 
above, bypass for RX only channel, press PTT to set.


Set Transmit tone Frequency as above for receive channel or select "OFF", 
press PTT to set.


Continue on to program all 16 channels or keep pressing PTT to bypass unused 
channels.  When "END" is displayed, turn radio off, reset Jumper CN7 to USER 
mode (| |-|) and turn radio on to operate.  Display will now show channel 
numbers.


When programming, if a mistake is made or it is decided to change or check a 
setting on a previous channel, rotate the channel selector knob while holding 
down the Monitor (speaker symbol) button to go forward or backward in the 
settings. Release the Monitor button and data can be changed by rotating the 
channel selector knob as usual. PTT and Squelch buttons operate as before. 